ISO3741 Comparison Method
Description
The ISO3741 comparison method
block determines the sound power levels based on calculations from ISO 3741:2010
Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods
for reverberation test rooms.
The sound power is calculated based on the comparison method where the sound pressure of the Noise sound source (ST)
is
compared to the sound pressure of a reference sound source (RSS)
with a known sound power in a reverberant test room.
Input
L'w(RSS)
Reference Source Sound Power, is the sound power level (dB) of the reference source in M
one-third-octave bands
from 100 Hz to 10 000 Hz specified in IEC61260. The Reference Sound Source should comply with ISO6926.
L'i,p(RSS)
Reference Source Sound Pressure, is the sound pressure level (SPL) of the reference sound source
measured in M
one-third-octave bands in I
microphone positions.
L'i,p(ST)
Noise Source Sound Pressure, is the sound pressure level (SPL) of the noise source measured in M
one-third-octave
bands in I
microphone positions.
L'i,p(B)
Background Noise Sound Pressure, is the sound pressure level (SPL) of the background noise measured in M
one-third-octave
bands in I
microphone positions.
Output
L'w
Noise Source Sound Power, is the determined sound power level (dB) of the noise source in M
one-third-octave
bands from 100 Hz to 10 000 Hz. Dependent on weighting the output can be determined as L'wA
being the A-weighted
sound power level.
Attributes
Attribute | Value |
---|---|
Name | ISO3741 |
Weighting | Z |
Static Pressure | ☐ 101.325 kPa |
Temperature | ☐ 20 C |
Humidity | ☐ 50 %RH |
Inputs | 4 |
Values with ☐ can receive external input.
Name
Name specifies the name of the block.
Weighting
Weighting specifies the sound power weighting which default is Z
Linear weighting and can be changed to A
A-weighting.
Static Pressure
Static Pressure specifies the static pressure during measurements.
Humidity
Humidity specifies the humidity during measurements.
Temperature
Temperature specifies the temperature during measurements
Inputs
Inputs specifies the number of inputs the block requires. This cannot be changed.