ISO3382 Noise Method
Description
The ISO3382 Noised Method
block determines the reverberation time based on calculations from ISO 3382-2:2008
Measurement of room acoustic parameters — Part 2: Reverberation time in ordinary rooms.
The reverberation time is calculated based on the interrupted noise method where a noise signal is interrupted and forms the rooms decay curve. Using exponential averaging the reverberation time T60, T30, or T20 is calculated.
Input
Noise [P,pos1]
is the interrupted noise signal that is M
samples long and can be repeated 1
to N
times.
Output
Reverberation times
is the calculated reverberation times in F
bands. Default one band pr octave from 100 Hz to 4000 Hz.
Attributes
Attribute | Value |
---|---|
Name | ISO3382NoiseMethod |
Mode | T30 |
Bands pr. octave | ☐ 1 |
Start frequency | ☐ 100 |
Stop frequency | ☐ 4000 |
Inputs | 2 |
Values with ☐ can receive external input.
Name
Name specifies the name of the block.
Mode
Mode specifies which type of reverberation time you want to calculate. You can choose between T60
, T30
, or T20
.
Bands pr. octave
Bands pr. octave species the number of bands you want to output pr octave.
Start frequency
Start frequency specifies the frequency which should be in the first band.
Stop frequency
Stop frequency specifies the frequency which should be in the last band.
Inputs